Sample Display - show fddi receive
FDDI Module Receive Errors:
---------------------------
CRC Overrun Invalid Frames
Slot Conn Circuit Errors Errors Frames Too Long
---- ---- ------- ---------- ---------- ---------- ----------
2 1 F21 0 0 0 0
1 entry in table.
sample [
<period in seconds>
] [circuit
<circuit name>
]
Displays data sampled from FDDI over a period of 10 seconds. You can change the
number of seconds over which you want to sample the data, and you can display sampled
data for a specific circuit only. The table includes the following information:
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Rx Frames Number of frames received.
Tx Frames Number of frames sent.
Rx Lack of Resources Number of packets received and discarded because of lack of
resources; for example, buffers.
Tx Lack of Resources Number of transmit packets discarded because of lack of resources;
for example, buffers.