Using Technician Interface Scripts
2-232 117380-A Rev. A
Sample Display - show ds1e1 stats circuit Boston
DS1E1 Logical Line I/O Statistics:
----------------------------------
Log Receive Receive Transmit Transmit Total
Slot Conn Line Circuit Bytes Frames Bytes Frames Errors
---- ---- ---- ---------- ---------- ---------- ---------- ---------- ----------
2 1 1 Boston 7150 275 190622 701 1257
Found 1 match out of 3 entries in table.
system errors [circuit
<circuit name>
]
Displays statistical information about system errors for all circuits or for a specific circuit.
The table includes the following information:
Slot Slot identifier.
Conn Connector identifier.
Log Line Logical line number for this line.
Circuit Name of the circuit associated with this line.
Unaligned Frames Number of frames containing a bit count not divisible by eight.
Internal Overflows Number of frames received with internal overflow errors.
Overflow Frames Number of overflow errors received on this line in which the device’s
FIFO buffer overflowed before obtaining the next DMA cycle. No
buffer resources are available.
Losses of Sync Number of instances of sync losses detected on this line. This error
statistic is equivalent to the “red alarm received” statistic on T1.