The logging information is written to a 1Kb buffer, instead of to the files. The contents of the
files is updated as follows:
• After you shut down the eKernel
• After the buffer is full. Remember the buffer is to midnight (after the date changes)
• At midnight (after the date changes) and there is something in the buffer, a new set of
files is created and the contents of the buffer is written to the files.
• Manually. If you want to read out recent information from the files, you can force an update
manually. Go to the eKernel window and select Refresh Logfile in the pull down menu
eKernel. See following window:
Figure 52: eKERNEL module refresh log file
The contents of these files are related to each other by means of identifiers. You can import
the files into a Spreadsheet application or Database Application of your choice, for further
analysis.
In the following sections, the contents of these files is explained.
ALARM Remove After GROUP id GROUP Description DEVICE id DEVICE area DEVICE
Outpgm eWEB user PINCODE Reason not processed
INrqs.csv
The file INrqs.csv contains detailed information on the incoming alarms. The following columns
are available:
• INRQS id
This is a tag for each input request. This tag is an identifier for each call. After the call is
processed, the tag is free again and is used for another incoming alarm. Therefore this
tag must always be seen in relation to the incoming alarm time and date. This INRQS id
is used in the two other LOG files that specifies the output processing.
• DATE
Date in format: YYYY-MM-DD
• TIME
Time in format: HH-MM-ss
• SET or RESET
eLOG
DECT Messenger Fundamentals March 2012 147