Figure 35: Rail with National Instruments FieldPoint IO Modules
The various types of IO modules that are supported for DECT Messenger can be classified as
control modules or I/O Modules. Table 11: Overview of supported control modules on page 111
and
Table 12: Overview of supported IO modules on page 112 give an overview of these
modules.
Table 11: Overview of supported control modules
Module Type Description Additional info
FP-1000 Control Module with
V.24 interface to
DECT Messenger
This module is as interface module between the
I/O modules and DECT Messenger. The FP-1000
can control up to 9 I/O modules directly. Up to 24
FP-1001 modules can be connected through
RS485 bus to expand the system with extra I/O
modules.
FP-1001 Expansion Control
Module
Must be connected to the RS485 interface on the
FP-1000. One FP-1001 can control up to 9 I/O
modules. The maximum number of FP-1001
modules one RS485 bus is 24.
PS-2 Power Supply 24 Volts DC.
Din rail Mounting rail The modules must be mounted on this rail.
Connecting National Instruments modules
DECT Messenger Fundamentals March 2012 111