Event Messages for Routers and BNX Platforms
9-52
Entity Code/Event Code 26/48
Decimal Identifier 16783920
Severity: Info
Message: Connector MAU<connector_no.> loaded Texas Instruments BUD/MAC <revision_no.>
on Silicon <revision_no.>.
Meaning: The Token Ring link module downloaded the Texas Instruments BUD/MAC microcode.
Entity Code/Event Code 26/51
Decimal Identifier 16783923
Severity: Info
Message: Connector MAU <connector_no.> loaded <token_ring_adaptor_microcode>.
Meaning: The Token Ring link module downloaded the specified version of the Token Ring adapter
microcode.
Entity Code/Event Code 26/59
Decimal Identifier 16783931
Severity: Info
Message: Connector MAU <connector_no.> transitioned to single station (only station on the ring).
Meaning: The Token Ring interface detected that it was the only station on the ring for 30 seconds.
The system is reconfiguring the Token Ring interface, reinitializing the interface and
flushing all routing tables associated with the interface.
Entity Code/Event Code 26/60
Decimal Identifier 16783932
Severity: Info
Message: Connector MAU <connector_no.> failed lobe wrap test during beacon auto-removal
process.
Meaning: The Token Ring interface has withdrawn itself from the ring while the ring was beaconing,
because it detected a fault on its own cable lobe.
Action: If this event occurs more than five times, replace the Token Ring hardware.