Event Messages for Routers and BNX Platforms
5-12
Entity Code/Event Code 5/226
Decimal Identifier 16778722
Severity: Fault
Message: Unknown Mem Error reg + <hex_value> accessed by NETMOD <network_module_ID>
(0=CPU), fatal error.
Meaning: For unknown reasons, a memory error occurred. The operating system running on the slot
reboots itself after generating this message.
Action: Call the Bay Networks Technical Response Center to report the error message.
Entity Code/Event Code 5/231
Decimal Identifier 16778727
Severity: Fault
Message: Backbone cable integrity lost, check cables, terminators and power switches
Meaning: One of the cables that makes up the ASN's backbone has been disconnected, or one of the
ASNs has been powered off.
Action: Check the cables, terminators and power switches. If all the cables and terminators are
intact and all the power switches are on, call the Bay Networks Technical Response Center
to report the error message.
Entity Code/Event Code 5/239
Decimal Identifier 16778735
Severity: Fault
Message: Memory error detected - <“Write violation” | “Tag violation” | “Extended address access”
| “Parity”> <register_of_memory_error_contents>
Meaning: If the message contains the word “Parity” error, the cause of the error is most likely a
hardware problem that requires a board replacement. Other errors most likely indicate a
software problem.
Action: Report this error message to the Bay Networks Technical Response Center.
Entity Code/Event Code 5/240
Decimal Identifier 16778736
Severity: Fault
Message: <error_message> VBM error detected (<error_bits>)
Meaning: A memory error occurred.
Action: Report this error message to the Bay Networks Technical Response Center.