Vista de pagina 318
FR Events
4-21
Entity Code/Event Code 32/20
Decimal Identifier 16785428
Severity: Warning
Message: Floppy controller timed out during status readback.
Sector number: <starting_sector_no.> count:<sec>
command:<command> operation:<operation>.
Meaning: An attempt to read data from the floppy controller did not succeed within the expected
time.
Action: If this error message persists, replace the floppy drive hardware.
FR Events
The Frame Relay service, referred to as the FR entity, issues the following event
messages. The entity code assigned to FR events is 25.
Fault Event
Entity Code/Event Code 25/10
Decimal Identifier 16783626
Severity: Fault
Message: System error, service attempting restart.
Meaning: Frame Relay experienced a fatal error and is restarting automatically. Frame Relay will
attempt to restart up to five times.
Action: Verify that the configuration is correct. Call the Bay Networks Technical Response Center
if Frame Relay fails to restart.
Warning Events
Entity Code/Event Code 25/4
Decimal Identifier 16783620
Severity: Warning
Message: Service configured but disabled for circuit <circuit_name>.
Meaning: Frame Relay is configured on the synchronous interface that supports the specified circuit.
However, the Frame Relay DLCMI MIB entry is marked Disabled.
Action: Use the Technician Interface to enable the Frame Relay DLCMI MIB entry to initiate
Frame Relay service.