FLOP Events
4-17
Entity Code/Event Code 32/5
Decimal Identifier 16785413
Severity: Warning
Message: Floppy seek operation failed.
Sector number:<starting_sector_no.> count:<sec> command:<command>
operation:<operation>.
Meaning: The seek command did not succeed in moving the read/write head to the specified
cylinder.
Action: Retry the operation. If that fails, use the Technician Interface to enter the unmount a: and
mount a: commands to reset the floppy controller and retry the operation. If the problem
persists, call the Bay Networks Technical Response Center.
Entity Code/Event Code 32/6
Decimal Identifier 16785414
Severity: Warning
Message: Floppy command was started but terminated abnormally.
Sector number:<starting_sector_no.> count:<sec> command:<command>
operation:<operation>.
Meaning: A command issued to the floppy controller terminated abnormally.
Action: Retry the operation. If that fails, use the Technician Interface to enter the
unmount a: and
mount a: commands to reset the floppy controller and retry the operation. If the problem
persists, call the Bay Networks Technical Response Center.
Entity Code/Event Code 32/7
Decimal Identifier 16785415
Severity: Warning
Message: Error during floppy DMA operation.
Sector number:<starting_sector_no.> count:<sec> command:<command>
operation:<operation>.
Meaning: An error has occurred within the floppy controller’s DMA unit during a read/write from/to
the floppy disk.
Action: Retry the operation. If that fails, use the Technician Interface to enter the unmount a: and
mount a: commands to reset the floppy controller and retry the operation. If the problem
persists, call the Bay Networks Technical Response Center.