Site Manager WAN Line Services Parameters
117021-A Rev. A A-13
Parameter: BofL Frequency
Path: HSSI Connector > Edit Line > Edit HSSI Parameters
Default: 1 second
Options: 0 to 60 seconds
Function: Specifies the interval in seconds between BofL transmissions. This parameter is
valid only if BofL is set to Enable.
After sending a BofL message, the router starts a timer that has a value equal to
five times the setting of this parameter. If the router does not receive a BofL
message from the remote peer before the timer expires, the router disables the
HSSI circuit, and then attempts to restart it.
Instructions: Accept the default, 1 second, or specify a new value, making certain that both
ends of the point-to-point connection are configured with the same value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.7.1.8
Parameter: MTU
Path: HSSI Connector > Edit Line > Edit HSSI Parameters
Default: 4608 bytes
Options: 3 to 4608 bytes
Function: Specifies the buffer size for the HSSI interface and, therefore, determines the
largest frame that can travel across the HSSI port.
Instructions: Set this parameter to a value appropriate for your network.
MIB Object ID: 1.3.6.1.4.1.18.3.4.7.1.9
Parameter: WAN Protocol
Path: HSSI Connector > Edit Line > Edit HSSI Parameters
Default: None
Options: Standard
| PassThru | PPP | SMDS | Frame Relay | ATM DXI
Function: Indicates which WAN protocol you enabled on this HSSI circuit.
Instructions: Accept this setting. Changing the protocol here will not reconfigure the
interface.
MIB Object ID: 1.3.6.1.4.1.18.3.4.7.1.12