Avaya Configuring ATM Services Manual de usuario Pagina 198

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 268
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 197
Configuring ATM Services
A-48 114056 Rev. A
Parameter: T316c
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 120
Options: 1 through 720
Function: Defines the Restart Request Sent on Channel timer value (in seconds). This
timer begins when the circuit sends a RESTART message to the network. The
circuit uses the RESTART message to return this individual VC on the interface
to the idle condition.
The Restart Request Sent on Channel timer stops when the circuit receives a
RESTART ACKNOWLEDGE message from the network.
If the timer expires before the circuit receives a RESTART ACKNOWLEDGE
message, the circuit can transmit as many RESTART messages as specified with
the Num Restarts ReXmitted parameter (refer to the parameter description later
in this section). If the circuit still does not receive a response, the circuit enters
the Null state until the appropriate maintenance action is taken.
Instructions: Accept the default, 120, or enter a value from 1 through 720.