114056 Rev. A A-9
ATM ARE Line Details
This section describes how to edit the line details for ATM ARE link modules and
the Model 5780 ATM router.
Parameter: Enable
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: Enable
Options: Enable | Disable
Function: Enables or disables the driver.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.3.2.1.2
Parameter: Interface MTU
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: 4608
Options: 1 through 9188 octets
Function: Specifies the largest packet size that the router can transmit on this interface.
Instructions: Enter a value that is appropriate for the network.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.3.2.1.9