Parameter: T310
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 10
Options: 1 through 60
Function: Defines the Call Proceeding Received timer value (in seconds). This timer
begins when the circuit receives a CALL PROCEEDING message from the
network.
If the signaling does not receive a CONNECT or RELEASE message before this
timer expires, it clears the connection for that virtual circuit.
Instructions: Accept the default, 10, or enter a value from 1 through 60.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.28
Parameter: T313
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 4
Options: 1 through 24
Function: Defines the Connect Sent timer value (in seconds). This timer begins when the
circuit sends a CONNECT message to the network.
The Connect Sent timer stops when the circuit receives a CONNECT
ACKNOWLEDGE message from the network (indicating the completion of the
ATM connection for that interface).
If the timer expires before the circuit receives a CONNECT ACKNOWLEDGE
message, the circuit clears the connection.
Instructions: Accept the default, 4, or enter a value from 1 through 24.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.29