Site Manager Parameters
114056 Rev. A A-43
Parameter: Max Parties in Multipoint Connections
Path: Configuration Manager > Protocols > ATM > ATM Signaling
(This parameter also appears in the Initial ATM Signaling Config window.)
Default: 1
Options: 0 through 32767
Function: Identifies the maximum number of simultaneous parties in a point-to-multipoint
connection allowed for this circuit.
Instructions: Accept the default, 1, or enter a value from 0 through 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.9
Parameter: Min Memory Threshold
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 20%
Options: 10%
| 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% | 100%
Function: Defines the minimum percentage of buffer memory necessary to enable a new
call.
Instructions: Accept the default, 20%, or select another percentage.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.11
Parameter: VPI
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 0
Options: 0 through 255
Function: Defines the virtual path identifier (VPI) for the signaling VC. The signaling VC
is a dedicated VPI/VCI pair reserved for signaling messages.
Instructions: Accept the default value, 0, or enter a value from 0 through 255.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.13
Caution: The signaling VC (0/5) and the ILMI VC (0/16) are reserved. These
VCs remain in an operational state as long as signaling is enabled on the ATM
interface. Because most ATM devices use these VPI/VCI pairs for signaling,
we recommend that you not change these values.