Site Manager Parameters
114056 Rev. A A-7
ATM FRE2 Physical Attributes
Edit ATM FRE2 physical attributes only when configuring a SONET OC-3 line.
Parameter: SVC Inactivity Timeout (Secs)
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: 1200 seconds
Options: 60 through 3600 seconds
Function: If the router receives or transmits no cells on an SVC for this number of
seconds, it closes the SVC, providing that you set the SVC Inactivity Timeout
Enable parameter to Enable.
Instructions: Enter an appropriate time, and be sure to set the SVC Inactivity Timeout Enable
parameter to Enable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.2.1.10
Parameter: Framing Mode
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: SONET
Options: SDH
| SONET
Function: Specifies either SDH or SONET framing mode.
Instructions: Select SDH or SONET.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.2.11.1.4
Parameter: Scrambling
Path: Configuration Manager > Circuits > Edit Circuits > Edit > Line Attributes
Default: Enable
Options: Enable
| Disable
Function: Enabling scrambling randomizes cell payload sufficiently to guarantee cell
synchronization. If you select Disable, cell synchronization problems may
result.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.2.11.1.5