Upgrading Routers from Version 5 to Version 10.0
B-2
Follow these guidelines to ensure that you are using a link module that can pass
X.25 certification:
Do not upgrade AFN hardware.
Do not replace link modules delivered after June 1992.
Upgrade link modules directly attached to the X.25 network that were
delivered before October 1991.
Inspect only the link modules directly attached to the X.25 network that were
delivered between October 1991 and June 1992. Determine which modules to
replace by removing the link module from the router and reading the revision
level of any MK5025 chip on that module. If the revision level is C03 or later,
do not replace.
Configuring Point-to-Point over a Synchronous Line
This section describes how to configure a point-to-point connection using the
Point-to-Point protocol over a synchronous line between a Version 5 and a Version
10.0 router.
HDLC Local/Remote Address Settings
On Version 5 routers, you must designate an HDLC “local address” and “remote
address” at each end of a point-to-point synchronous line. The router at each end
receives packets at the designated local address and send packets to the remote
(destination) address.
For each of these parameters, you use Version 5 NCL to either
Set an implicit address value of DCE (which the router recognizes as a value
of 0x01) or DTE (0x03).
Set a unique explicit address value in the hexadecimal range 0x00 to 0x99,
inclusive.
Note: If you need hardware to upgrade your router for X.25 support, order it
from Bay Networks. Specify that the router needs this hardware to satisfy X.25
certification requirements.