Component Flag Description
disabled (dimmed); the option
is deactivated by force and you
cannot manage the option.
• The values are YES and NO.
The default value is NO
(disabled).
Memory Monitor. See 2.2.4 MEMCHECK_PERIOD Determines the time period in
seconds when the Memory
monitor wakes up (after start-up
or the last memory check
attempt).
The values are 1800 (0.5 hrs) to
86400 (24 hrs). The default
value is 86400 (24 hrs).
SIP-traffic monitor DOS_PACKET_RATE Determines the maximum
number of packets per second
that is allowed.
SIP_traffic monitor DOS_MAX_LIMIT Specifies how many packets past
DOS_PACKET_RATE the IP
Deskphone can receive before
packets are dropped.
If packets are received at a rate
of DOS_PACKET_RATE +1,
then packets start getting
dropped after the time specified
in DOS_MAX_LIMIT (in
seconds).
SIP-traffic monitor DOS_LOCK_TIME Specifies the amount of time (in
seconds) the IP Deskphone stops
processing packets after
DOS_MAX_LIMIT is reached.
If DOS_PACKET_RATE is < 1,
other values are ignored and
packets are not dropped.
Logging System LOGSIP_ENABLE Allows the administrator to
enable or disable SIP-logging.
• If the parameter is YES, the
SIP-logging Manager is active
and starts logging SIP incoming
and outgoing packages into the
log files in FFS.
• The values are YES and NO.
The default value is NO (the
Diagnostics and troubleshooting
306 SIP Software for Avaya 1200 Series IP Deskphones-Administration January 2012