GeoTel Features User Manual VSTAT Alarms
P0602482 Ver. 04.03 Avaya Page 423
VSTAT 11001
MESSAGE
Data received from less lines (<# received>) than expected
(<# expected>)
SEVERITY
4
PROBABLE CAUSE
During the current update request cycle, vstat received data from less lines than in a
previous cycle. This alarm may signal an error in internal processing in tcad that
indicates a more severe problem.
ACTION
Confirm that ccm and tms are configured for appropriate number of lines.
Confirm the vstat and tcad executable is from appropriate patch level.
Restart the component.