CONFMGMT 11002
MESSAGE
Failed to create bridge for conference [<conference name>].
SEVERITY
4
PROBABLE CAUSE
1. The Network Interface Controller (NIC) is not connected.
2. There is no network timing.
3. The Network Control Daemon (NCD) process is not connected to the
Avaya MPS.
4. There is a software configuration problem (possibly incompatible
packages).
5. There are more serious software/hardware problems.
ACTION
1. Verify Avaya MPS/TMS hardware configuration is correct. Refer to TMS
instructions for details.
2. Verify the Spans specified in Sync List for Reference Clock A and B are
in Service. If spans are off line, refer to system documentation for
instructions to get the Spans back in Service.
3. Verify that NCD is running.
4. Ensure that the PERImps package is compatible with the PERIbrdge
package. Refer to the system documentation for information regarding
software package compatibility and support.
5. Restart the system. If the alarm persists, contact your local Avaya MPS
support staff.