GeoTel Features User Manual VENGINE Alarms
P0602482 Ver. 04.03 Avaya Page 291
VENGINE 25079
MESSAGE
[Para <block_name>/<1>] Pipe to CALLdaemon is broken
SEVERITY
3
PROBABLE CAUSE
1. A user-defined call function is not functioning properly.
2. There is an error which may indicate a more severe problem.
ACTION
1. Review the call function code for errors.
2. If this error appears only once and without other incidents, the system
should recover automatically. If this error appears more than once or is
accompanied by abnormal system behavior, contact your local Avaya
MPS support staff.