Avaya Media Processing Server Series Alarm Reference Manual (Software Release 2.1) Manual de usuario Pagina 395

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 452
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 394
GeoTel Features User Manual VENGINE Alarms
P0602482 Ver. 04.03 Avaya Page 395
VENGINE 29016
MESSAGE
[Para <block_name>/
<1>] Norestart condition arrived due to soft termination
SEVERITY
3
PROBABLE CAUSE
The application was soft terminated and will not automatically restart. Soft
termination is usually initiated by a kill signal (either from PeriView or from the
kill command). This alarm does not necessarily indicate a system error.
ACTION
If the application was knowingly soft terminated, no action is required. If the
application consistently soft terminates without reason, there may be more serious
problems. Contact your local Avaya MPS support staff.
Vista de pagina 394
1 2 ... 390 391 392 393 394 395 396 397 398 399 400 ... 451 452

Comentarios a estos manuales

Sin comentarios