Connecting BayStack AN and ANH Systems to a Network
4-18 114074 Rev. A
The BOOTP Relay Agent Forwarding Table window lists the connector and
input IP address on the left, and the connector and output IP address on the
right.
If you enter an IP address of an interface that is not configured,
??? appears
instead of the connector (for example,
??? 192.32.23.3). If you configure
the IP address, Site Manager replaces the
??? with the appropriate connector.
6. Click on Done to exit the window.
BOOTP Relay Agent Interface Parameters
Parameter: Input IP Address
Default: None
Options: Any valid IP address
Function: Specifies the IP interface that receives BOOTP request packets from an
external network. This interface must have BOOTP configured on it.
Instructions: Enter the IP address of the interface through which the router will receive
BOOTP requests.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.8.3.2.1.3
Parameter: Output IP Address
Default: None
Options: Any valid IP address
Function: Specifies the IP interface that forwards BOOTP request packets to an
external network.
Instructions: Enter the IP address of the interface through which the router will forward
BOOTP requests.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.8.3.2.1.4