Avaya Connecting BayStack AN and ANH Platforms to a Network Manual de usuario Pagina 135

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 178
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 134
Troubleshooting Network Boot Problems
114074 Rev. A A-7
get wfDrivers.*.0
A combination of the following settings should appear within the list of
drivers, according to your AN or ANH configuration:
Use the
set command to correct any settings that are incorrect. For
example, if the router has a Token Ring port and the
wfDrivers.wfTMS380Load.0 setting is not 2147483648, enter the
following command to correct it:
set wfDrivers.wfTMS380Load.0 2147483648;commit
If the router is Netbooting with a synchronous connector, enter the
following command to display the information about the connector,
where <connector> is the connector number:
get wfSyncEntry.*.1.
<connector>
Make sure that external clocking is set.
If the router is Netbooting with an Ethernet connector, enter the following
command to display the information about the connector, where
<connector> is the connector number:
get wfCSMACDEntry.*.1.
<connector>
Identifying Remote Connectivity Problems
The sections that follow provide guidelines for isolating a router addressing
problem or a Netboot problem. Refer to the appropriate section.
Displaying Messages from the AN/ANH Console
Displaying Statistics and Error Messages
Guidelines for Using Packet Capture
Guidelines for Using a LAN Protocol Analyzer
wfDrivers.wfQsccSyncLoad.0 = 2147483648 COM ports
wfDrivers.wfQsccEnetLoad.0 = 2147483648 Ethernet ports
(nonrepeating)
wfDrivers.wfRptrLoad.0 = 2147483648 Ethernet repeater
ports (ANH only)
wfDrivers.wfTMS380Load.0 = 2147483648 Token Ring ports
Vista de pagina 134