Configuring IGMP Relay
303527-A Rev. 00
9-13
Using Site Manager
Configuring Unsolicited Reports on an Upstream Interface
By default, an IGMP-R device sends an unsolicited group report on the upstream
interface. After an interval of 10 seconds, IGMP sends a second report.
Using the BCC or Site Manager, you can specify the interval between the first and
second unsolicited report or configure IGMP Relay to send one unsolicited report
only.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Protocols
.
The Protocols menu opens.
2. Choose
IP
. The IP menu opens.
3. Choose
IGMP
. The IGMP menu opens.
4. Choose
Entry
. The IGMP Entry Interface Parameters
window opens.
5. Set the
Relay Circuit Type
parameter.
Site Manager:
Relay Circuit Type
parameter: page A-22
6. Click on
Apply
, and then click on
Done
. You return to the Configuration Manager
window.