Configuring Frame Relay Services
3-18 117376-B Rev. 00
Grouping Service Records for Multiline Mode
You can configure two or more service records to run in multiline mode (for
information about Bay Networks proprietary implementation of multiline, see
pa
ge 2-29). Service records that you group for multiline must:
• Reside on two separate physical ports
• Have the same DLCI numbers
• Not use hybrid mode
To configure multiline mode:
Site Manager Procedure
You do this System responds
1. Click on the Protocols menu in the
Configuration Manager menu bar.
The Protocols menu opens.
2. Click on
Frame Relay. The Frame Relay menu opens.
3. Click on Services. The Frame Relay Service List window
opens.
4. Click on the Multiline button. The Services Multiline With window
opens.
5. Click on the Add button. The Add Multiline Services window
opens.
6. Choose the frame relay interface you want
to configure for multiline.
The frame relay interface entry becomes
highlighted.
7. Click on Select. The Add Multiline Services window
closes. Site Manager moves the record of
the frame relay interface from the Add
Multiline Services window to the Services
Multiline With window.
8. Set the Multiline Algorithm to Choose
Line parameter. Use Help or see the
parameter description on page A-
34.
9. Click on Apply.
10.Click on Done. You return to the Frame Relay Service
List window.