Customizing Frame Relay
117376-B Rev. 00 3-15
To enable congestion control:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on Edit Circuit. The Frame Relay Circuit Definition
window opens.
3. Click on Interfaces. The Frame Relay Interfaces window
opens.
4. Set the following parameters, using Help
or the parameter descriptions that begin
on page A-
9:
• Congestion Control
• Congestion Timer
• Congestion Counter
• Congestion Method (applies only
when you enable traffic shaping)
5. Edit other parameters if you want, and
click on Apply.
6. Click on Done. You return to the main Configuration
Manager window.
7. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
8. Click on Edit Circuit. The Frame Relay Circuit Definition
window opens.
9. Click on Services. The Frame Relay Service List window
opens.
10.Click on PVCs. The FR PVC List for Service window
opens.
11.Set the following parameters, using Help
or the parameter descriptions that begin
on page A-
29:
• Congestion Control
• Congestion Timer
• Congestion Counter
• Congestion Method (applies only
when you enable traffic shaping)
Comentarios a estos manuales