Error Threshold and Monitored Events
Error threshold and monitored events together establish a criterion to evaluate the
quality of the router’s frame relay network connection. The error threshold is the
number of faulty status messages that must occur to terminate the connection.
Monitored events is the number of status message exchanges, within which
number those errors occur.
For example, if you accept the default of 3 for the error threshold, and the default
of 4 for monitored events, three status exchange errors in a sequence of four
attempted exchanges brings the connection down. Similarly, if you set error
threshold to 5 and monitored events to 10, five status exchange errors in a
continuous sequence of ten attempted exchanges brings the connection down.
To specify error threshold and monitored events values:
Note: Error Threshold and Monitored Events do not function if you set
Mgmnt Type to DLCMI None.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on Edit Circuit. The Frame Relay Circuit Definition
window opens.
3. Click on Interfaces. The Frame Relay Interfaces window
opens.
4. Set the following parameters, using Help
or the parameter descriptions that begin
on page A-
7:
• Polling Interval
• Full Enquiry Interval
• Error Threshold
• Monitored Events
5. Edit other parameters if you want, and
click on Apply.
6. Click on Done. You return to the main Configuration
Manager window.