Installing ATM Link Modules and Routing Engines in BN Platforms
3-2
114951-B Rev 00
Figure 3-2. ARE SONET/SDH Link Module LEDs
Table 3-1 describes the LED functions, which are identical for the DS-3, E-3, and
SONET/SDH interface link modules.
Note that all LEDs light briefly during powerup, reset, and hot-swap of the link
module
Table 3-1. Functions of the DS-3, E-3, and SONET/SDH Link Module LEDs
LED Function
MODULE RESET Lights when the link module is resetting. During a hardware reset, the link module
returns to a known (inactive) state. The exception is the frame, which sources idle
cells and maintains SONET framing.
ATMC (ATM
Coprocessor)
RESET
Lights when the ATM Coprocessor (local microcontroller on the link module) is in
reset mode. This occurs during the upload of the driver code from the ARE to link
module memory.
SW LOAD Indicates that the driver code has been successfully loaded into link module memory,
and is ready to forward traffic. A blinking SW LOAD LED indicates a software fault.
TEST Indicates that the port is disabled or looped back.
RDI (Remote
Defect Indication)
Lights when the framer receives an indication that the far-end device has detected a
receive defect/failure or is unable to achieve frame synchronization. Note that the
LED is valid only when the driver software is running (in which case, the SW LOAD
LED is on).
LINK Indicates that SONET frame synchronization has been achieved. If the link module
detects a signal, but frame synchronization is not achieved, this LED blinks. If the link
module does not detect a signal, the LED remains off. This LED is valid only when
the driver software is running (in which case, the SW LOAD LED is on).
FAIL Lights when the link module fails diagnostics or bypasses diagnostics (as is the case
during the hot-swap procedure).
FAIL
ARE
SONET/SDH
MODULE
RESET
ATMC
RESET
SW
LOAD
TEST
RDI
LINK
RECEIVE
TRANSMIT
ALM0006A
Vista de pagina 41
1 2 ... 37 38 39 40 41 42 43 44 45 46