Using Technician Interface Software
2-8
308657-14.00 Rev 00
Parameter: Port Type
Attribute Name: wfSerialPortType
Attribute Number: 7
Default: 1 (Technician Interface)
Options: 1 (Technician Interface)
|
2 (Printer)
Function: Configures the port for either Technician Interface (Console or Modem)
or Printer. (The Printer option is not supported at this time.)
Instructions: Set according to your console requirements.
Command:
set wfSerialPortEntry.7.
<port_no.> <option>
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.11.1.1.7
Parameter: Baud Rate
Attribute Name: wfSerialPortBaudRate
Attribute Number: 8
Default: 9600
Options: 9600
|
4800
|
1200
|
600
|
300
Function: Specifies the rate of data transfer between the console and the router.
Instructions: Set according to your console requirements.
Command:
set wfSerialPortEntry.8.
<port_no.> <option>
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.11.1.1.8