Table 11-1. BFE X.25 Packet-Level Parameter Settings
Parameter Setting
Enable Enable
Network Address Type BFE_NETWORK
PDN X.121 Address Parameter is ignored
DDN IP Address Specify the IP address assigned to your BFE
connection.
Sequence Size MOD8
Restart Procedure Type DTE_RESTART
Default Tx/Rx Window Size Range is 2 to 7. This setting should match the default
value configured in the BFE. This value should be
coordinated with the X.25 service record value.
Default Tx/Rx Packet Length Options include 128, 256, 512, and 1024. This setting
should match the default value configured in the BFE.
This value should be coordinated with the X.25 service
record value.
Number of incoming SVC
channels
Zero (0). BFE does not support the one-way logical
channel incoming facility.
Incoming SVC LCN Start Parameter is ignored
Number of outgoing SVC
channels
Any valid nonzero setting
Bidirectional SVC LCN Any valid nonzero setting
Number of outgoing SVC
channels
Zero (0). BFE does not support the one-way logical
channel outgoing facility.
Outgoing SVC LCN Start Parameter is ignored
Number of PVC channels Zero (0). BFE does not support PVCs.
PVC LCN Start Parameter is ignored
T1 Timer, T2 Timer, T3 Timer,
T4 Timer
BFE has no special requirements for any of these four
parameters.
Flow Control Negotiation Set to on if you do not want to use the default values
configured in the BFE for this link.
(continued)