Editing Frame Relay Parameters
4-23
Data Path Chooser Parameter
Parameter: Data Path Chooser
Default: None
Options: Random
| Address Based
Function: Specifies how the multiline circuit distributes traffic over its data paths.
Instructions: Select Random to send data alternately over the two paths. This method
ensures even distribution among the lines, but the packets arrive out of
sequence. Select Address Based if the traffic between the same source and
destination address pair is always going over the same data path. This
method ensures the data arrives in sequence.
MIB Object ID: 1.3.6.1.4.1.18.3.5.4.1.1.23
Deleting PVCs
To delete a PVC, complete the following steps:
1. From the Configuration Manager window (Figure 4-1), select
ProtocolsFrame RelayInterfaces.
The Configuration Manager displays the Frame Relay Interface List window
(Figure 4-2).
2. Click on PVCs to display the Frame Relay PVC List window
(Figure 4-3).
3. Select the PVC you want to delete.
4. Click on Delete.
The Configuration Manager asks you to confirm the deletion.
5. Click on OK to delete the PVC.
After you delete a PVC, it may reappear on the list of active PVCs if the switch
provider does not delete it. As soon as the switch provider removes the PVC, the
Configuration Manager dynamically deletes the PVC from the list.