Editing Frame Relay Parameters
4-7
Parameter: Polling Interval
Default: 10 seconds
Range: 5 to 30 seconds
Function: Specifies the interval between Status Inquiry messages that the router
transmits. Status Inquiry messages cause a network response in the form
of a Link Integrity Verification message or Full Status message.
Successful completion of the request/response “handshake” verifies the
status of the router/Frame Relay network link.
Instructions: We recommend that you accept the default value, 10 seconds. If the
default value does not match what the network requests, enter a value that
is appropriate for your network in the range of 5 to 30 seconds. Polling
Interval does not function if you set the Mgmnt Type parameter to
DLCMI None.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.10
Parameter: Full Enquiry Interval
Default: 6
Range: 1 to 255 polling intervals
Function: Specifies the interval between Full Status Inquiry messages that the router
transmits. Full Status Inquiry messages cause the network to send a Full
Status Report message, which lists all PVCs, the PVC status (active or
inactive), and whether the PVC is new or previously established. This
parameter works with the Polling Interval parameter.
The default value, 6, tells the router to send a Full Status Inquiry every 6
polling intervals. For example, with a Polling Interval of 10 and a Full
Enquiry Interval of 6, the router transmits a Full Status Inquiry every 60
seconds; with a Polling Interval of 20 and a Full Enquiry Interval of 30,
the router transmits a Full Status Inquiry every 10 minutes (600 seconds).
Instructions: Enter a value between 1 and 255, according to what the network dictates.
Full Enquiry Interval does not function if you set the Mgmnt Type
parameter to DLCMI None.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.11