Monitoring ATM Using the BCC show Command
303514-A Rev. 00
B-27
show sonet current
The
show sonet current
command displays portions of the SONET entries table.
The output includes the following information:
Slot/<Module>/Conn The slot, module, and connector number of the SONET circuit.
Circuit Name of the circuit associated with this line.
Sec into Interval The number of seconds into the current 15-minute interval.
# of Intervals The number of complete 15-minute intervals.
Line Codin
g
The line codin
g
on this circuit. The line codin
g
options are:
•B3ZS
HDB3
Line Type Status The line status of the interface. The possible status values are:
NoAlarm
- no alarm present
RRAI
- receivin
g
yellow remote alarm indication
TRAI -
transmittin
g
yellow remote alarm indication
RAIS
- receivin
g
Alarm Indications Si
g
nal (AIS) failure state
TAIS
- transmittin
g
AIS failure state
LOF
- receivin
g
Loss of Frame (LOF) failure state
LOS
- receivin
g
Loss of Si
g
nal (LOS) failure state
Loopback
- loopin
g
the received si
g
nal
TestCode
- receivin
g
a test pattern
LowSignal
- low si
g
nal
Line Stats
Slot/<Module>/Conn The slot, module, and connector number of the SONET circuit.
Circuit Name of the circuit associated with this line.
Interval The current interval.
LESs The number of line errored seconds (LESs) in the current interval.
An LES is a second in which one or more codin
g
violations occurred
or one or more LOS defects were detected.
SEFSs The number of severely errored framin
g
seconds (SEFSs) in the
current interval. An SEFS is a second with one or more OOF errors
or an AIS defect.
UASs The number of unavailable seconds (UASs) in the current interval.
LCVs The number of line codin
g
violations (LCVs) in the current interval.
A line codin
g
violation is a count of both bipolar violations (BPVs)
and excessive zero (EXZ) error events.