Site Manager Parameters
303514-A Rev. 00
A-39
Parameter: T308
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 30
Options: 1 to 180
Function: Specifies the Release Sent timer value (in seconds). This timer begins when the
circuit sends a RELEASE message to initiate clearing of an SVC. Sending a
RELEASE message places the network in the Release Request state.
The Release Sent timer stops when the circuit receives either a RELEASE
message (that is, both the circuit and the network sent RELEASE messages at
the same time) or a RELEASE COMPLETE message from the network.
If the timer expires before the circuit receives one of these messages, the circuit
transmits the RELEASE message again. If the circuit still does not receive a
response, the circuit releases the call reference and begins a restart procedure.
Instructions: Accept the default, 30, or enter a value from 1 to 180.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.26
Parameter: T309
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 10
Options: 1 to 540
Function: Specifies the SAAL Data Link Connect timer value (in seconds). This timer
begins when a signaling AAL malfunction occurs.
The SAAL Data Link Connect timer stops when the circuit reestablishes SAAL
(that is, when the circuit sends an AAL-ESTABLISH-REQUEST and receives
an AAL-ESTABLISH-CONFIRM message).
If the timer expires before the circuit can reestablish SAAL, the circuit clears the
connection.
Instructions: Accept the default, 10, or enter a value from 1 to 540.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.27