Customizing Signaling
303514-A Rev. 00
4-53
Setting the Receive SDU Size
Bay Networks suggests that you accept the default value of 4608 bytes for the
maximum AAL CPCS SDU size that the control VC supports in the receive
direction. Most packet sizes fall well within this limit. However, you can set the
receive SDU size to any value from 1 to 65,535 bytes.
Using the BCC
To change the receive SDU size for the signaling control VC, navigate to the
signaling VC prompt (for example,
box; atm/11/1; signaling/11/1;
signaling-vc/11/1/0/5
) and enter:
rx-sdu-maximum
integer
integer is the maximum SDU size that you want the signaling VC to receive.
For example, the following command changes the maximum receive SDU size to
65,535 bytes:
signaling-vc/11/1/0/5#
rx-sdu-maximum 65535
signaling-vc/11/1/0/5#
To change the receive SDU size for the ILMI control VC, navigate to the ILMI
VC prompt (for example,
box; atm/11/1; signaling/11/1; ilmi-vc/11/1/0/16
) and
enter:
rx-sdu-maximum
integer
integer is the maximum SDU size that you want the ILMI VC to receive.
For example, the following command changes the maximum receive SDU size to
65,535 bytes:
ilmi-vc/11/1/0/16#
rx-sdu-maximum 65535
ilmi-vc/11/1/0/16#