Configuring ATM Services
4-60
303514-A Rev. 00
Modifying SAAL Timers
You can change the default values for SSCOP/SAAL timers. For each timer,
Table 4-4 provides the BCC name, Site Manager name, default value, range, and
description.
Note:
Bay Networks recommends that you leave these timers set to their
default values unless instructed to change them by Bay Networks Customer
Service or your switch provider.
Table 4-4. SSCOP/SAAL Timer Descriptions
BCC Name
Site
Manager
Name
Default
Value Range Description
poll-timer Poll Timer
7 1 to 120 Specifies the SSCOP poll timer value (in tenths of a
second). This value sets the allowable time between
POLL PDU transmissions.
The poll timer ensures that the receiver continues to
return a solicited status (STAT) PDU to the sender on a
re
g
ular basis. The timely receipt of STAT PDUs restarts
the poll timer and allows for more efficient transmission
error recovery.
keep-alive-
timer
Keep Alive
Timer
20 1 to 120 Specifies the SSCOP keep alive timer value (in tenths of
a second). This value sets the allowable time between
POLL PDU transmissions if there are no pendin
g
sequence data (SD) PDUs.
The keep alive timer is
g
enerally
g
reater than the poll
timer and
g
reater than the len
g
th of one round-trip delay.