Avaya DMC DECT Fundamentals - Communications Server 1000 Manual de usuario Pagina 59

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 340
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 58
Figure 22: Critical points
Locating cell centres
Figure 23: Cell centres on page
60 shows the following:
• stairwell
• second floor plan
A cell centre is located by placing the deployment tool at one critical point, for example P1,
then using the deployment handset to obtain a change in audio quality. The audio quality
change determines the cell boundary contour. This process is repeated at an adjacent critical
point, for example P2. Where the cell boundaries of both critical points meet is the cell centre.
The cell centre position is marked on a floor plan. The cell centre determines the location of a
basestation, shown in
Figure 23: Cell centres on page
60, as arc 2C1.
Deployment
DMC DECT Fundamentals August 2012 59
Vista de pagina 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 339 340