Installing CS 1000E cabinet wiring to the MDF
Consult the work order to determine the CS 1000E cabinet-to-MDF cabling route, then perform
the steps in Installing CS 1000E cabinet wiring to the MDF on page
157.
Figure 92: Meridian 1 PBX 11C Cabinet
Installing CS 1000E cabinet wiring to the MDF
1.
Identify the UTP Cat 5 twenty five pair MDF cable.
Label both ends of the cable with the cabinet jack number.
2. Connect the cabinet end of the cable.
Insert the Amphenol connector on the cable into the appropriate cabinet connector
jack.
3. Run the cable to the MDF.
4. Terminate the cable on the MDF.
Installing additional IPE shelves or CS 1000E cabinets
DMC DECT Fundamentals August 2012 157