connections. For DMC8 types NTCW00AB and NTCW01AB, connect from
basestation 1 to basestation 8.
Note:
To support basestations 5, 6, 7, and 8 on NT8D37 (AA and DC) IPE modules
requires 24 tip and ring pair backplane to I/O panel connections. To re-cable
NT8D37 from 16 pair to 24 pair, see Avaya Communication Server 1000M and
Meridian 1: Large System Installation and Commissioning (NN43021-310),
Appendix B.
Table 36: External housing basestation to BIX MDF connections
External housing base
station number
External housing connector
box in number
MDF connection
Basestation 1
3 T8
4
R8
2
T9
5
R9
Basestation 2
3 T10
4 R10
2 T11
5 R11
Basestation 3
3 T12
4 R12
2 T13
5 R13
Basestation 4
3 T14
4 R14
2 T15
Basestation 5
4 T16
5 R16
6 T17
3 R17
Basestation 6
4 T18
5 R18
6 T19
3 R19
Installing the basestation