Configuring WAN Line Services
B-22
308648-14.00 Rev 00
show ft1e1 stats
The
show ft1e1 stats
command displays FT1 or FE1 input/output statistical
information for all FT1 or FE1 modules, or for a specific circuit.
This command allows for the following command filters (flags) and filter
arguments:
The output contains the following information:
-circuit
<circuit_name>
Displays information about the specified circuit only.
<circuit_name>
Displays information about the specified circuit only.
Slot/Conn Slot location of the FT1 or FE1 module within the chassis
and the connector number.
Circuit Name of the circuit associated with this line.
State State of the line driver: Down, Init (initializing), Not
Present (enabled, but not yet started), or Up.
The Not Present state occurs for several reasons. For
example, the link module may not be physically present
in the chassis; the software may be booting and has not
yet initialized the driver software; the slot may be running
diagnostics; or there may be a problem with the
configuration.
Errors:
Receive Number of receive errors.
Transmit Number of transmit errors.
Bytes:
Receive Number of octets received without error.
Transmit Number of octets transmitted without error.
Frames:
Receive Number of frames received without error.
Transmit Number of frames transmitted without error.
(continued)
Comentarios a estos manuales