Configuring MCE1 and MCT1 Services
308648-14.00 Rev 00
7-19
Setting the MCT1 Line Coding
T1 uses bipolar format for signals. In bipolar format, alternating positive and
negative pulses on the digital line signify the number 1, and the absence of a pulse
signifies 0 (see Figure 6-2 in Chapter 6). A long string of zeros would cause the
line to lose synchronization due to lack of pulses. Nortel Networks provides a
line-coding mechanism to maintain synchronization.
By default, the MCT1 interface uses bipolar with 8 zero substitution (B8ZS) line
coding. You can select AMI line coding instead.
B8ZS line coding replaces a block of eight consecutive binary 0s with an 8-bit
B8ZS code. For more information on B8ZS line coding, see “Enabling or
Disabling Bipolar with 8 Zero Substitution (B8ZS)” in Chapter 6.
AMI line coding is also bipolar: a binary 0 is transmitted as zero volts, and a
binary 1 is transmitted as either a positive or negative pulse, opposite in polarity to
the previous pulse. (When configured for AMI line coding, the MCT1 link module
remains synchronized upon receiving up to 45 consecutive zeros.)
Using the BCC
To change the line coding, navigate to the mct1 prompt (for example,
box
;
mct1/1/1
) and type:
port-line-coding
variable
For example:
mct1/1/1#
port-line-coding ami
mct1/1/1#
port-line-coding b8zs
Using Site Manager
See the Line Coding parameter on page A-30 for information.
Note:
If the T1 receive path detects a B8ZS code word when the line is
configured for AMI coding, the router generates a log message and an SNMP
trap.