Configuring WAN Line Services
9-4
308648-14.00 Rev 00
Using the BCC
To set the clock parameters, navigate to the fe1/1/1 prompt (for example,
box
;
fe1/1/1
) and type:
primary-clock-source
variable
secondary-clock-source
variable
For example:
fe1/1/1#
primary-clock-source internal
fe1/1/1#
secondary-clock-source loop1
Using Site Manager
You access the clock parameters via the window that opens after you set the port
application mode. How you access this window is based on if you have already
configured the port.
For an unconfigured FE1 link module
The first time you configure a port, the Edit FE1 Clock Parameters window
opens automatically. When you set these clock parameters, you define the
timing sources for the selected port only.
For a configured FE1 link module
Display the FE1 Port Parameters window (FE1 Connector > Edit Logical
Lines > Port Details > FE1 Port Parameters).
To set the clock parameters, complete the following tasks.
Site Manager Procedure
You do this System responds
1. In the window containing the clock
parameters, select a primary clock source
option.
2. Set the
Primary Clock
parameter.
Click on
Help
or see the parameter
description on page A-49.
Site Manager sets the primary clock to
the value you specified.
3. Select the secondary (backup) clock
source option.
(continued)