Avaya Configuring WAN Lines Services Manual de usuario Pagina 215

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 462
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 214
Configuring FT1 Services
308648-14.00 Rev 00
8-13
Using Site Manager
See the Accept Loopback Request parameter on page A-48 for information.
When you enable Accept Loopback Request, you can set the type of loopback you
want. See “Setting a Loopback Configuration” on page 8-14
.
Setting the Loop Retention Interframe Time Fill
In the BCC, the FDL Loop Interframe Fill parameter is set to mark by default,
which enables the detection of loop retention code when the remote end is in line
or payload loopback. When you set this parameter to loop-retention, the loop
retention interframe time fill (IFTF) for the facility data link (FDL) is enabled
after it sends loop-up code.
Using the BCC
To set this parameter, navigate to the ft1 prompt (for example,
box
;
ft1/1/1
) and
type:
fdl-loop-interframe-timefill
variable
For example:
ft1/1/1#
fdl-loop-interframe-fill loop-retention
Vista de pagina 214
1 2 ... 210 211 212 213 214 215 216 217 218 219 220 ... 461 462

Comentarios a estos manuales

Sin comentarios