Configuring SDLC Services
4-24 114053 Rev. A
Parameter: Slow Poll Timer
Default: 1000 milliseconds
Range: 1 through 64000
Function: Allows polling to continue (using this timer) when the Fast Poll Count
Limit expires. This parameter operates with the Slow Poll Count Limit
parameter.
Instructions: Enter a value from 1 through 64000.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.7.5.1.24
Parameter: Slow Poll Count Limit
Default: 65535
Range: 1 through 65535
Function: Controls the number of times a link station is removed from the polling
list before sending an outage message to a device. This parameter
operates with the Slow Poll Timer parameter.
Instructions: Enter a value from 1 through 65535, where 1 causes SDLC to generate an
outage after the first Slow Poll Timer expires, and 65535 specifies an
infinite number of retries.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.7.5.1.25