Configuring Ethernet, FDDI, and Token Ring Services
A-12 117020-A Rev. A
Parameter: Requested TTRT (ms)
Path: Configuration Manager > FDDI Connector > Edit Line > Edit FDDI
Parameters > Expert > Path Attributes > FDDI Path Attributes
Default: 165 milliseconds (ms)
Options: Variable. This value must be greater than the value specified for the TVX Lower
Bound (ms) parameter and less than or equal to the value specified for the
T_Max Lower Bound (ms) parameter.
Function: Specifies the target token rotation time carried in claim frames issued by the
FDDI station.
Instructions: Accept the default of 165 ms or enter a new value in milliseconds.
MIB Object ID: 1.3.6.1.4.1.18.3.4.4.1.32
Parameter: LER Cutoff
Path: Configuration Manager > FDDI Connector > Edit Line > Edit FDDI
Parameters > Expert > Port Attributes > FDDI Port Attributes
Default: 7
Options: 4 to 15
Function: Specifies the link error rate estimate at which a link connection is broken. It
ranges from 10
-4
to 10
-15
and is reported as the absolute value of the base 10
logarithm.
Instructions: Accept the default value of 7 or specify a new value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.15.4.3.1.17
Parameter: LER Alarm
Path: Configuration Manager > FDDI Connector > Edit Line > Edit FDDI
Parameters > Expert > Port Attributes > FDDI Port Attributes
Default: 8
Options: 4 to 15
Function: Specifies the link error rate estimate at which a link connection generates an
alarm. It ranges from 10
-4
to 10
-15
and is reported as the absolute value of the
base 10 logarithm of the estimate.
Instructions: Accept the default value of 8 or specify a new value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.15.4.3.1.18