Configuring Ethernet Services
117020-A Rev. A 2-5
Enabling or Disabling BofL Messages
With BofL enabled, the router sends polling messages from this Ethernet interface
to all systems on the local network.
BofL messages are enabled by default on every Ethernet interface. You can
disable and enable BofL messages on an interface.
Setting the BofL Timeout
With BofL enabled, a network timeout will occur if five periods elapse without a
successful BofL message transmission. When timeout occurs, the router
automatically disables and reenables the Ethernet interface. For example, if you
set the BofL Timeout interval to 10 seconds, the interface must successfully
transmit a BofL message within 50 seconds.
The BofL Timeout interval is 5 seconds by default. You can change the interval of
BofL messages to a value from 1 to 60 seconds.
Setting BofL Retries
By default, the router makes five attempts to transmit a BofL message before
declaring the Ethernet interface down. With router redundancy enabled, the
default is four attempts.
You can specify the number of transmission attempts, from 1 to 60 retries, before
the router declares the circuit down.
Note: The router does not send BofL messages if it is already transmitting
regular data traffic.
Site Manager: BofL Enable parameter: page A-2
Site Manager: BofL Timeout parameter: page A-2