Configuring Dial Services
A-66 117353-A Rev. A
Parameter: Full Enquiry Interval
Path: Demand Circuits: Dialup > Demand Circuits > FR Circuits > FR Demand
Circuits > Demand Intf. > FR Demand Interface List
Backup Circuits: Dialup > Backup Circuits > Frame Relay > FR Primary
Interface Definition > Backup Def. > FR Backup Interface
Default: 6
Options: 1 to 255 polling intervals
Function: Specifies the interval between full status inquiry messages that the router
transmits. Full status inquiry messages cause the network to send a full status
report message, which lists all PVCs, the PVC status (active or inactive), and
whether the PVC is new or previously established. This parameter works with
the Polling Interval parameter.
The default value, 6, tells the router to send a full status inquiry every 6 polling
intervals. For example, with a polling interval of 10 and a full enquiry interval
of 6, the router transmits a full status inquiry every 60 seconds; with a polling
interval of 20 and a full enquiry interval of 30, the router transmits a full status
inquiry every 10 minutes (600 seconds).
Instructions: Enter a value from 1 to 255, according to what the network dictates. Full
Enquiry Interval does not function if you set Mgmnt Type to DLCMI None.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.11