18 Chapter 1 Installing the Companion system
P0609345 01
b Remove the cover by lifting it up. Refer to the following figure.
Figure 4 Opening the RPI cover
3 Hang the RPI on the two screws and tighten the screws.
4 Install the remaining two screws.
5 Feed the power cord through the bottom of the RPI.
6 Route it through the clip and around the strain relief support. The following figure
shows how to route the power cord.
Figure 5 RPI components
7 Route the power cord to the input power socket just to the left of PSU 1, on the left.
8 Connect the plug to the socket.
9 Follow the appropriate wiring instructions in the wiring charts in the next section,
“Wiring the base station and connecting the RPI”.
PSU 1 PSU 2
(if equipped)
Up to 16 outputs
(TCM + power)
Up to
16
inputs
(TCM)
Connection board
Jumper lead to PSU 2
Power cord
Grounding strap
Power supply cabling
Strain relief support
Clip
Grounding plates
Ferrite rings
The RPI-8 has grounding straps and
plates fitted to allow an upgrade to
an RPI-16.