Using Technician Interface Scripts
2-336 303560-A Rev 00
Sample Display - show hssi sample
HSSI Sampled Data over 10 seconds
----------------------------------
Rx Tx Rx Lack of Tx Lack of
Slot Conn Circuit Frames Frames Resources Resources
---- ---- ------- ---------- ---------- ---------- ----------
3 1 H31 11 12 0 0
1 entry in table.
Sample Display - show hssi sample circuit H31
HSSI Sampled Data over 5 seconds
----------------------------------
Rx Tx Rx Lack of Tx Lack of
Slot Conn Circuit Frames Frames Resources Resources
---- ---- ------- ---------- ---------- ---------- ----------
3 1 H31 5 6 0 0
Found 1 matches out of 1 entry in table.
stats
[
circuit
<circuit name>
]
Displays HSSI input/output statistical information for all HSSI circuits or for a specific
circuit. The table contains the following information:
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Receive Bytes Number of octets received without error.
Receive Frames Number of frames received without error.
Transmit Bytes Number of octets transmitted without error.
Transmit Frames Number of frames transmitted without error.
Total Errors Total number of errors of all types.