•Modes:
This group of options apply to execution modes and include: Restart, Wait for
Exit, Start on Reboot, Web, Standby, and Error Trapping.
• Restart Mode:
Restart Mode refers to the ability of an application to repeat the call
processing cycle for a new call, when the execution cycle for the current call
is complete.
Enable the restart mode to restart an application at the conclusion of each
execution cycle. Disable the restart mode to force the application to terminate
after conclusion of the initial execution cycle.
Call processing applications, by design, process calls one call at a time. That
is, when the execution cycle for call is complete, the application is ready to
accept the next call. You must enable the restart mode for this to occur. If you
disable restart mode, the application terminates after execution of the first call
cycle.
Typically, administrative applications, because of the nature of the jobs they
perform, should not restart when they complete their execution cycle. (For
example, applications that perform initialization operations probably should
terminate after a single execution cycle.)
• Wait for Exit Mode:
The Wait for Exit mode allows an application to execute completely before
the next application starts. Applications start in the order in which selected
applications are listed in the Locations scrolling window in the Application
Management tool. This parameter applies only to applications that you
configured as Administrative at the Execution Type parameter. (It is inactive
when you select Call Processing as the Execution Type.)
Typically, administrative applications perform prerequisite initialization or
maintenance functions needed for the successful execution of other
applications. These functions can include resetting a counter or reintializing
shared memory. This parameter allows for applications performing
prerequisite functions to execute completely, before the next application
starts.
Enable Restart.
The application execute recurrently. It can be terminated by selecting
Terminate with the Application Management tool. (Default for Call
Processing applications)
Disable Restart.
When the application terminates, it does not restart automatically. It
must be restarted by selecting Start with the Application Management
tool. (Default for Administrative applications)