Configuring Frame Relay Services
3-2 114058 Rev. A
Adding and Deleting Service Records
A service record is a data structure that allows flexible grouping and
characterization of PVCs. You can add and delete service records from your
Frame Relay interfaces. When you add a new service record, it automatically has
one PVC to which you must assign a DLCI number.
Adding and Deleting PVCs
You can add or delete PVCs from already existing service records. You can add
PVCs either individually, or in a range. If you want to add one PVC, enter one
DLCI number. If you want to add several PVCs, enter the appropriate range of
DLCI numbers in the format
< lowest DLCI number> - < highest DLCI number>
Site Manager Path: Select a port that you have configured for Frame Relay. The Edit
Connector window appears. Select Edit Circuit. The Frame Relay Circuit Definition
window appears. Select Services. The Frame Relay Service List window appears. Select
Add | Delete.
If you want to delete a service record, select that service record and then select Delete.
The service record no longer exists.
If you want to Add a service record, select Add. The Frame Relay Virtual Circuit window
appears. Enter the DLCI number.
Site Manager: Service Name parameter: page A-8
Site Manager: DLCI Number parameter: page A-8
Site Manager Path: Select a port that you have configured for Frame Relay. The Edit
Connector window appears. Select Edit Circuit. The Frame Relay Circuit Definition
window appears. Select Services. The Frame Relay Service List window appears. Select
PVCs.
If you want to delete a PVC, select that PVC and then select Delete. The PVC no longer
exists.
If you want to add a PVC, select Add > Frame Relay Virtual Circuit window and enter the
DLCI number.
Site Manager: DLCI Number parameter: page A-8
Comentarios a estos manuales